Critical threshold value is less than warning threshold value.

Solution ID:ORA-13912

Type: Oracle

Cause

An attempt was made to call SET_THRESHOLD procedure with the critical threshold value less than the warning threshold value.

Actions

Check the operator and threshold values and reissue statement.

Try the following links for this error:


http://docs.oracle.com/cd/E16655_01/server.121/e26079/e12700.htm


https://community.oracle.com/message/2285827